Deployment and Installation Center
Websense TRITON Enterprise v7.6.x

Go to the table of contents Go to the previous page Go to the next page Go to the index
Custom Deployment > Installing Web Security components > Remote Filtering Communication Screen

The external IP address or host name of the firewall or gateway must be visible from outside the network. If you enter a host name, it must be in the form of a fully-qualified domain name: <machine name>.<domain name>
Important 
Remember whether you entered an IP address or a host name here. When installing the Remote Filtering Client on user machines, you must enter this address in the same form (IP address or domain name).
Note 
It is a best practice to use IP addresses, rather than host names, unless you are confident of the reliability of your DNS servers. If host names cannot be resolved, Remote Filtering Clients will be unable to connect to the Remote Filtering Server.
The external communication port can be any free port in the range 10-65535 on this machine. This port receives HTTP/HTTPS/FTP requests from external Remote Filtering Client machines (i.e. user machines, running Remote Filtering Client, outside the network). The default is 80. If a Web server is running on this machine, it may be necessary to use a different port.
Note 
The external network firewall or gateway must be configured to route traffic, typically via PAT or NAT, from Remote Filtering Client machines to the internal IP address of this machine.
The internal communication port can be any free port in the range 1024-65535 on this machine. The default is 8800. This is the port to which remote client heartbeats are sent to determine whether a client machine is inside or outside the network. The external network firewall must be configured to block traffic on this port. Only internal network connections should be allowed to this port.


Go to the table of contents Go to the previous page Go to the next page Go to the index
Custom Deployment > Installing Web Security components > Remote Filtering Communication Screen