Go to the table of contents Go to the previous page Go to the next page View or print as PDF
Troubleshooting > Other reporting issues > Real-Time Monitor is not running
Real-Time Monitor is not running
Web Security Help | Web Security Solutions | Version 7.8.x
This alert is displayed when the Websense RTM Server service is stopped.
Use the Windows Services tool to verify that all 3 Real-Time Monitor services are started, and to start any of the following services that have stopped:
*
*
*
If any service will not start:
*
*
Check the WebsenseRTMMemoryOutput0.log file (located, by default, in the C:\Program Files or Program Files (x86)\Websense\Web Security\rtm\logs directory) for information about Real-Time monitor memory usage.
*
If the service is running, but the alert continues to appear, this may indicate that Real-Time Monitor was unable to register with Policy Server. Verify that the Policy Server associated with this Real-Time Monitor instance is running, and that the Real-Time Monitor machine can communicate with the Policy Server machine on port 55836 (encrypted communication) or 55856 (non-encrypted communication).
If the services do start, make sure that they are configured for Automatic (not Manual) startup.

Go to the table of contents Go to the previous page Go to the next page View or print as PDF
Troubleshooting > Other reporting issues > Real-Time Monitor is not running