v7.8.2 Release Notes for Websense V-Series Appliances : Operating tips
|
![]() |
Log onto the V-Series manager, go to the Configuration > System page to confirm and adjust, if necessary, the Time and Date settings, paying particular attention to the time zone setting.
|
![]() |
If the upgraded appliance is a Policy Server, log onto TRITON console, go to the Web Security manager Settings > General > Policy Servers page and add the appliance. Next go to the TRITON console Appliances tab and register the appliance.
|
![]() |
When Policy Broker is run on a V-Series appliance (configured as the Full policy source), all Policy Servers that point to that Policy Broker (configured as User directory and filtering) must be installed on V-Series appliances as well. You cannot install and run Policy Servers on off-box machines and point them to a Policy Broker that runs on an appliance. This configuration is not supported.
|
![]() |
Teamed NICs share the load under one common identity, with multiple adapters load-balancing under a single IP address. This is also known as link aggregation or trunking.
|
![]() |
When Web Security Gateway (Anywhere) is deployed and Content Gateway Integrated Windows Authentication (IWA) is configured, if the appliance hostname is changed, IWA will immediately stop working. To repair the IWA configuration, log onto Content Gateway Manager, unjoin the stale domain and join the domain with the new hostname.
|
![]() |
When configuring schedule backups to a remote storage location (FTP server or Samba share), make sure that the account used for backup file creation has read and write permissions. If you plan to use the option to automatically delete backup files older than some period of time, you must use an account that has delete permissions for the backup file directory and its subdirectories.
|
![]() |
In a multiple appliance deployment, after restoring the configuration of a Policy source appliance, restart any Filtering only or User directory and filtering appliances in your network to ensure that user requests are filtered correctly.
|
![]() |
![]() |
![]() |
![]() |
v7.8.2 Release Notes for Websense V-Series Appliances : Operating tips
|