When SIEM integration is enabled for Websense Web Security solutions, Websense Multiplexer passes Internet activity data (logs) from Filtering Service to both Log Server and the configured SIEM product.
If Multiplexer is not running or not available, a failover feature ensures that Filtering Service passes log data to Log Server. No data, however, is sent to the SIEM product.
To resolve this issue in a Websense appliance-based deployment:
1.
If you have not enabled the Multiplexer service, go to the Administration > Toolbox > Command Line Utility in Appliance Manager.
Select multiplexer, then use the enable command.
2.
If Multiplexer has already been enabled, but is not running, go to the Status > General page in Appliance Manager and restart the Websense Web Security module.
To resolve this issue in a software-only deployment:
1.
*
*
Linux: Use the /opt/Websense/WebsenseDaemonControl command to start (or restart) Multiplexer.
2.
*
Windows: Use Task Manager to stop the MuxCtrl.exe process, then use the Services tool to start Websense Multiplexer.
*
Linux: Kill the MuxCtrl process, then use the /opt/Websense/WebsenseDaemonControl command to start Multiplexer.