Deployment and Installation Center
Websense TRITON Enterprise v7.6.x

Go to the table of contents Go to the previous page Go to the next page Go to the index
Websense Content Gateway > Installing Websense Content Gateway

Complete these steps to install Websense Content Gateway (Content Gateway) on a server in a software-base deployment of Websense software. In a Websense-appliance-based deployment, Content Gateway is already installed on the appliance.
1.
Disable any currently running firewall on this machine for the duration of Content Gateway installation. Bring the firewall back up after installation is complete, opening ports used by Content Gateway.
a.
At a command prompt, enter service iptables status to determine if the firewall is running.
b.
c.
After installation, restart the firewall. In the firewall, be sure to open the ports used by Content Gateway on this machine. See Ports for more information.
2.
Download the WebsenseCG76Setup_Lnx.tar.gz tar archive, from mywebsense.com to a temporary directory:
mv <installer tar archive> wcg_v76
tar -xvzf <installer tar archive>s
Important 
If SELinux is enabled, set it to permissive or disable it before installing Websense Content Gateway. Do not install or run Websense Content Gateway with SELinux enabled.
4.
Note 
Up to the configuration summary (Step 17 below), you can quit the installer by pressing CTRL-C. If you choose to continue the installation past the configuration summary and you want to quit, do not use CTRL-C. Instead, allow the installation to complete and then uninstall it.
If you want to change your answer to any of the installer prompts, you will be given a chance to start over at the first prompt once you reach the configuration summary; you do not have to quit the installer.
Enter n to end the installation, and return to the system prompt.
Enter y to continue the installation. If you choose to run Content Gateway after receiving this warning, performance may be affected
6.
Read the subscription agreement. At the following prompt, enter y to continue installation or n to cancel installation.
Password:> (note: cursor will not move as you type)
This account enables you to log on to the management interface for Content Gateway, known as Content Gateway Manager. The default username is admin.
To create a strong password (recommended), use 8 or more characters, with at least 1 each of the following: capital letter, lower case letter, number, special character.
Important 
The password length must be 16 characters or less. Also, it cannot contain the following characters:
*
' (backtick; typically shares a key with tilde, ~)
Note 
As you type a password, it may seem that nothing is happening—the cursor will not move nor masked characters shown—but the characters are being accepted. After typing a password, press Enter. Then repeat to confirm it.
Enter the Policy Server IP address (leave blank if integrating with Data Security only): [] >
Use dot notation (i.e., xxx.xxx.xxx.xxx). Press Enter to leave this field blank if this Content Gateway deployment is with Websense Data Security only.
Ports preceded by numbers in the list are considered the 9 ports for Content Gateway. Ports preceded by letters are needed if you have subscribed to Websense Web Security Gateway or Web Security Gateway Anywhere.
Change a port assignment if it will conflict with another application or process on the machine. Otherwise, leave the default assignments in place.
If you do not want to use these ports for Content Gateway, or if the installation program indicates that a port conflict exists, make any necessary changes. Any new port numbers you assign must be between 1025 and 65535, inclusive.
Websense Content Gateway requires at least 2 interfaces to support clustering. Only one active network interface is detected on this system.
13.
If two or more network interfaces are found on this machine, you are asked whether this instance of Content Gateway should be part of a cluster:
'1' - Select '1' to configure Websense Content Gateway
for management clustering. The nodes in the cluster
will share configuration/management information
automatically.
Enter the number that represents your clustering environment. If you do not want this instance of Content Gateway to be part of a cluster, enter 2.
><cluster_name>
[<default IP address>] >
14.
For Content Gateway to act as a Web cache, a raw disk must be present on this machine. If no raw disk is detected, the following prompt appears:
a.
Select available disks from the list. Selected disks become dedicated cache disks and cannot be used for any other purpose. Cache disks must be raw. Aggregate disk cache size should not exceed 147 GB.
Select available disk resources to use for the cache. Remember that space used for the cache cannot be used for any other purpose.
Warning 
Although it might be listed as available, do not use an LVM (Logical Volume Manager) volume as a cache disk.
e.
Continue based on your choice in Step b, pressing X when you have finished configuring cache disks.
Websense Content Gateway can send information about scanned content to Websense, Inc. This information helps Websense, Inc. improve filtering and scanning technology and accuracy.
Alarm Email Address : <email address>
CACHE DISKS LISTED ABOVE WILL BE CLEARED DURING
INSTALLATION!! CONTENTS OF THESE DISKS WILL BE
COMPLETELY LOST WITH NO CHANCE OF RETRIEVAL.
Installer CANNOT detect all potential disk mirroring
systems. Please make sure the cache disks listed
above are not in use as mirrors of active file
If you want to make changes, enter n to restart the installation process at the first prompt. To continue and install Content Gateway configured as shown, enter y.
Important 
If you enter y to proceed but you decide you want to cancel the installation, do not attempt to quit the installer by pressing CTRL-C. Allow the installation to complete. Then uninstall it.
Note the location of the certificate required for Content Gateway Manager:
/root/WCG/content_gateway_ca.cer. See the Getting Started section of the Content Gateway Manager Help for information on importing this certificate.
You may receive an email from Websense Content Gateway (to the address you specified during installation for receiving alerts) with "WCG license download failed" in the subject line. This does not mean a problem occurred with the installation; this alert is generated because a subscription key has not been entered yet. You will enter a key as part of initial configuration tasks.


Go to the table of contents Go to the previous page Go to the next page Go to the index
Websense Content Gateway > Installing Websense Content Gateway