Interface setup tip
If the P2 interface is used and it is in the same subnet as P1, the default gateway is automatically assigned to P2, which is bound to eth1. You should perform a test to ensure that outbound packets can reach the Internet.
Avoiding port conflicts
See the ports list for a table of the Websense software module versions that are compatible with each appliance version.
Check the ports article to avoid port conflicts if you plan to make a change from a default port.
For example, if you want to use an HTTP proxy server port that is different from the default port (8080), be sure to check the ports list first, to avoid conflict with ports already in use by the X-Series.
Web security deployment tips
Policy source tips
*
When Policy Broker is run on a X-Series appliance (configured as the full policy source), all Policy Server instances that point to that Policy Broker must be installed on X-Series appliances (configured as user directory and filtering appliances). You cannot install and run Policy Servers on off-box machines and point them to a Policy Broker that runs on an appliance. This configuration is not supported.
*
*
Subscription key tip
*
Integrated Windows Authentication (IWA) tip
*